| | 77 | |
| | 78 | == Deye Sun-12k-SG04LP3 Power-Shaving und Nullspeise-Parameter |
| | 79 | |
| | 80 | || Parameter (-Name) || im Winterbetrieb || im Sommerbetrieb || |
| | 81 | || //Zero Export to CT// || ja|| ja|| |
| | 82 | || //Solar Sell// || nein|| //ja??//|| |
| | 83 | || //Max Sell Power// || 12000 W|| 12000 W|| |
| | 84 | || //Zero-export Power// || 100 W|| 100 W|| |
| | 85 | || //Energy pattern// || Batt First|| Load First|| |
| | 86 | || //Grid Peak shaving// || 1400 W|| 1300 W|| |
| | 87 | |
| | 88 | === Winter-Zeitplan (erprobt mit 2,3 kWp Solar) |
| | 89 | |
| | 90 | * Start: Ende Oktober |
| | 91 | * Ende: Anfang März |
| | 92 | |
| | 93 | Einstellungen: |
| | 94 | |
| | 95 | * //Time Of Use//: ein |
| | 96 | |
| | 97 | || Grid Charge || Gen |||| Time || power || Batt || |
| | 98 | || V || || 00:05 || 04:35 || 12000 W|| 56,9 V|| |
| | 99 | || || || 04:35 || 09:00 || 12000 W|| 56,9 V|| |
| | 100 | || || || 09:00 || 13:00 || 12000 W|| 56,9 V|| |
| | 101 | || || || 13:00 || 17:00 || 12000 W|| 56,9 V|| |
| | 102 | || || || 17:00 || 21:00 || 12000 W|| 56,9 V|| |
| | 103 | || || || 21:00 || 00:05 || 12000 W|| 56,9 V|| |
| | 104 | |
| | 105 | |
| | 106 | === Sommer-Zeitplan (Entwurf, nicht erprobt) |
| | 107 | |
| | 108 | * Start: Anfang März |
| | 109 | * Ende: Ende Oktober |
| | 110 | |
| | 111 | Einstellungen: |
| | 112 | |
| | 113 | * //Time Of Use//: ein |
| | 114 | |
| | 115 | || Grid Charge || Gen |||| Time || power || Batt || |
| | 116 | || || || 00:05 || 04:35 || 12000 W|| 48,0 V|| |
| | 117 | || || || 04:35 || 09:00 || 12000 W|| 49,6 V|| |
| | 118 | || || || 09:00 || 13:00 || 12000 W|| 49,6 V|| |
| | 119 | || || || 13:00 || 17:00 || 12000 W|| 49,6 V|| |
| | 120 | || || || 17:00 || 21:00 || 12000 W|| 49,6 V|| |
| | 121 | || || || 21:00 || 00:05 || 12000 W|| 48,0 V|| |
| | 122 | |